Keysight (Agilent HP) E8363A Repair Service

E8363A Microwave VNA 45MHz- 40GHz
We repair and calibrate the Agilent E8363A Vector Network Analyzer in our full-service lab. Obsolete equipment is our specialty. Free evaluations.
The Keysight E8363A vector network analyzer is a member of the PNA Series network analyzer platform and provides the combination of speed and precision for the demanding needs of today's high frequency, high-performance component test requirements. The PNA Series meets these testing challenges by providing the right combination of fast sweep speeds, wide dynamic range, low trace noise and flexible connectivity. The E8363A provides TRL/LRM calibration (four-receiver enabled) for waveguide, on-wafer, and in-fixture devices. Source attenuators, bias-tees and direct receiver access are optionally available for active device and extended dynamic range measurements.
e8363a
Any failures or unforeseen issues identified during the calibration phase will be detailed in an estimate submitted for your approval prior to any further action. Repair charges are determined by the actual time and materials required. Please be aware that customers are responsible for all associated shipping costs, to and from our location. This initial estimate is provided free of charge.
E8363A Specifications – click to expand

E8363A Specifications

  • PNA-series vector network analyzer
  • Windows-based with color display, LAN and GPIB interfaces
SpecificationValue
Frequency range45 MHz to 40 GHz
E8363A Options – click to expand

E8363A Options

  • 010, Time Domain
  • 014, Configurable Test Set
  • 016, Receiver Step Attenuators
  • 080, Frequency Offset
  • 081, Reference Receiver Switch
  • 082, Scalar Mixer Calibration
  • 083, Vector Mixer Calibration
  • UNL, Extended Power Range and Bias Tees
  • 1CM, Rack Mount Kit
Agilent / HP E8363A Error Codes – click to expand

Agilent E8363A Error Messages

The E8363A messages below are the ones that point to hardware, followed by what a failed performance test means on this model.

E8363A on-screen error messages

MessageMeaning and where to look
PHASE LOCK LOSTThe A11 phase lock board sees too little reference-receiver signal to lock. Cause can be in the source, signal separation (couplers, switch) or receiver path. Check the A10 frequency reference output and the reference receiver first.
SOURCE UNLEVELEDOn the E8363A check cables W37/W38 from the A23/A24 detectors to the A16 test set motherboard and W39 to the A21 SOMA 50. One port only: replace that port's detector. Both ports: replace A16.

E8363A failed performance test – likely cause

Failed testWhat it points to
Source power accuracy / linearityRun the source calibration adjustment; if it still fails, the source (A12 source) is suspect.
Source maximum power outputFollow the signal through the separation path (switch, couplers, attenuators) to find the loss.
Frequency accuracyMeasure the rear-panel 10 MHz REF OUT; more than about 10 Hz off calls for the 10 MHz reference adjustment.
Trace noiseRarely fails alone; run the receiver calibration adjustment, then suspect the A6 SPAM board.
Receiver compression / noise floor / dynamic accuracyPoints to the A31–A34 receivers or the A6 SPAM board. Receivers are identical, so swapping two channels confirms a bad one.
Calibration coefficientsTracking terms only: run the receiver calibration adjustment. Any other error term failing means a hardware fault.
System crosstalkLoose RF cable, or isolation loss in the receivers or the receiver/test set motherboard. Tighten all cables and receiver screws first.

SCPI error ranges

RangeClass
−100 to −199Command errors
−200 to −299Execution errors
−300 to −399Device-specific errors
−400 to −499Query errors

Hardware error on your E8363A? Analyzer Repair Inc. repairs and calibrates the Agilent E8363A in-house in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

Based on the Agilent PNA Series Service Guide E8362A/E8363A/E8364A (E8364-90001).

Agilent / HP E8363A Replaceable Parts – click to expand

Agilent E8363A Replaceable Assemblies and Part Numbers

Assembly-level part numbers for the E8363A. Check your options before ordering option-only parts.

ReferenceAssemblyAgilent part numberNotes
A1Keypad assemblyE8356-60001
A2Display assemblyE8356-60002Inverter 0950-3379, lamp 2090-0386, glass 1000-1161 sold separately
A3Front panel interface boardE8361-60061
A4Power supply assembly0950-4599
A6Signal processing ADC module (SPAM) boardE8356-60006
A8Fractional-N synthesizer boardE8364-60099A9 second Frac-N with Option 080
A10Frequency reference boardE8364-60004
A11Phase lock boardE8364-60005
A12Source 20E8362-60002Exchange E8362-69002
A14System motherboardE8364-60006
A15CPU board, 500 MHzE8364-60025
A16Test set motherboardE8364-60007
A17LOMA 10 (LO multiplier/amplifier)5087-7127Exchange 5087-6127
A18MA 20 (multiplier/amplifier)5087-7128Exchange 5087-6128
A19Splitter5087-7139
A20LODA (LO distribution assembly)5087-7129Exchange 5087-6129
A21SOMA 50 (source multiplier/amplifier)5087-7130Exchange 5087-6130
A22Switch splitter5087-7132Exchange 5087-6132
A23, A24Channel R1 / R2 detector5087-7133
A25, A26Test port couplers5086-7518
A27, A30Channel A / B first converter (mixer)5087-7122Exchange 5087-6122
A28, A29Channel R1 / R2 first converter (mixer)5087-7145Exchange 5087-6145
A31–A34Receiver modules (A, R1, R2, B)E8364-60003Exchange E8364-69003
A35Receiver motherboardE8364-60010
A36, A3760 dB source step attenuators33325-60004Option UNL
A38, A39Bias tees (with cable)5087-7233Option UNL
A40Floppy disk drive0950-2782
A41Programmed hard disk driveE8801-60063
B1Fan3160-10853 required

Part obsolete? Many E8363A assemblies are no longer sold new. Analyzer Repair Inc. repairs E8363A boards and RF modules at the component level in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

From the Agilent PNA Series Service Guide E8362A/E8363A/E8364A (E8364-90001).