Keysight (Agilent HP) E8358A Repair Service

E8358A PNA Network Analyzer 300kHz-9GHz
Send us your Agilent E8358A Network Analyzer for full repair and calibration. Our veteran-owned lab offers free estimates and quick turnaround.
The Keysight E8358A vector network analyzer is a member of the PNA Series network analyzer platform and provides the combination of speed and precision for the demanding needs of today's high frequency, high-performance component test requirements. The PNA Series meets these testing challenges by providing the right combination of fast sweep speeds, wide dynamic range, low trace noise and flexible connectivity.
e8358a
Any failures or unforeseen issues identified during the calibration phase will be detailed in an estimate submitted for your approval prior to any further action. Repair charges are determined by the actual time and materials required. Please be aware that customers are responsible for all associated shipping costs, to and from our location. This initial estimate is provided free of charge.
E8358A Specifications – click to expand

E8358A Specifications

  • PNA-series vector network analyzer
  • Windows-based with color display, LAN and GPIB interfaces
SpecificationValue
Frequency range300 kHz to 9 GHz
E8358A Options – click to expand

E8358A Options

  • 010, Time Domain
  • 014, Configurable Test Set
  • 1CM, Rack Mount Kit
Agilent / HP E8358A Error Codes – click to expand

Agilent E8358A Error Messages

Error and fault messages for the Agilent E8358A network analyzer (9 GHz), with the assemblies the service manual points to.

E8358A on-screen error messages

MessageMeaning and where to look
PHASE LOCK LOSTThe A11 phase lock board sees too little reference-receiver signal to lock. Cause can be in the source, signal separation (couplers, switch) or receiver path. Check the A10 frequency reference output and the reference receiver first.
SOURCE UNLEVELEDThe source leveling loop is open. On the E8358A start with the A12 source assembly and the A16 test set motherboard.

E8358A failed performance test – likely cause

Failed testWhat it points to
Source power accuracy / linearityRun the source calibration adjustment; if it still fails, the source (A12 source) is suspect.
Source maximum power outputFollow the signal through the separation path (switch, couplers, attenuators) to find the loss.
Frequency accuracyMeasure the rear-panel 10 MHz REF OUT; more than about 10 Hz off calls for the 10 MHz reference adjustment.
Trace noiseRarely fails alone; run the receiver calibration adjustment, then suspect the A6 SPAM board.
Receiver compression / noise floor / dynamic accuracyPoints to the A18–A21 receivers or the A6 SPAM board. Receivers are identical, so swapping two channels confirms a bad one.
Calibration coefficientsTracking terms only: run the receiver calibration adjustment. Any other error term failing means a hardware fault.
System crosstalkLoose RF cable, or isolation loss in the receivers or the receiver/test set motherboard. Tighten all cables and receiver screws first.

SCPI error ranges

RangeClass
−100 to −199Command errors
−200 to −299Execution errors
−300 to −399Device-specific errors
−400 to −499Query errors

Hardware error on your E8358A? Analyzer Repair Inc. repairs and calibrates the Agilent E8358A in-house in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

Based on the Agilent E8356A/E8357A/E8358A PNA Service Guide (E8356-90002).

Agilent / HP E8358A Replaceable Parts – click to expand

Agilent E8358A Replaceable Assemblies and Part Numbers

Major replaceable assemblies for the Agilent E8358A, from the Agilent E8356A/E8357A/E8358A PNA Service Guide (E8356-90002).

ReferenceAssemblyAgilent part numberNotes
A1Keypad assemblyE8356-60001
A2Display assemblyE8356-60002
A3Front panel interface boardE8361-60061
A4Power supply assembly0950-3384
A6SPAM boardE8356-60006
A8Fractional-N synthesizer boardE8356-60008
A10Frequency reference boardE8356-60010
A11Phase lock boardE8356-60011
A12Source assemblyE8356-60012Exchange E8356-69012
A14MotherboardE8356-60014
A15CPU board, 500 MHzE8364-60025Replaces 266 MHz board; also needs HDD E8801-60063
A16Test set motherboardE8356-60049
A17LODAE8356-60017
A18–A21Receiver modules (A, R1, R2, B)E8356-60018Exchange E8356-69018; 4 required
A22Switch splitter5087-7019Exchange 5087-6019
A23, A24Test port couplers5087-7020Exchange 5087-6020
A25, A2670 dB step attenuators33321-60056
A27, A2835 dB receiver step attenuators33325-60008Option 015
A30Floppy disk drive0950-2782
A31Programmed hard disk driveE8801-60063For 500 MHz CPU (E8356-60076 for 266 MHz CPU)
B1Fan3160-10853 required

Part obsolete? Many E8358A assemblies are no longer sold new. Analyzer Repair Inc. repairs E8358A boards and RF modules at the component level in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

From the Agilent E8356A/E8357A/E8358A PNA Service Guide (E8356-90002).

Located in: Network Analyzers