Keysight (Agilent HP) 8719A Repair Service
Product model
8719A Microwave Vector Network AnalyzerServices
Description

Repair prices
8719A Specifications – click to expand
8719A Specifications
Frequency range: 130 MHz to 13.5 GHz, Up to 95 dB dynamic range, Directivity of 40 dB, source match of 30 dB, load match 35 dB from 0.13 to 2 GHz and 30 dB from 2 to 20 GHz, Resolution of 100 kHz, Impedance of 50 ohms, Switch type is mechanical, maximum input level of +20 dBm.
8719A Options – click to expand
8719A Options
option 001 provides 1 Hz resolution for narrow-band or long devices. It has tuned receivers and variable-bandwidth IF filters, and provides over 85 dB of dynamic range. Option 003 boosts the forward dynamic range to 95 dB; solutions to 100 dB are available.
HP 8719A Error Messages – click to expand
HP 8719A Error Messages
The HP 8719A (130 MHz to 13.5 GHz) reports faults as text messages on screen. Hardware (H) messages point to a failed assembly; user (U) messages mean a setup, calibration or cable issue; (M) messages are information.
8719A notes
- The 8719A source is phase locked through the R sampler; a missing or weak R signal shows up as phase lock errors.
- Normal CW power at the 8719A test port is about +10 dBm ±2 dB; low power points to the source group.
- The rear-panel A15 green LED should be on and the red LED off, and all nine A8 green LEDs on, before troubleshooting anything else.
8719A hardware error messages
| Message | Type | Meaning |
|---|---|---|
| PHASE LOCK CAL FAILED | H | The phase lock calibration failed. Either the R sampler or its control and bias voltages are faulty, or the source pretune is off. Check the green sampler control wire (about +0.2 V) and the ±15 V bias. |
| Other phase lock error messages | H | Any phase lock error on screen means the source group (A11 phase lock, YIG oscillator, A12 reference, A14 fractional-N) or the R sampler path needs checking. |
| POWER SUPPLY SHUT DOWN! | H | One or more A8 post-regulator supplies shut down from over-current, over-voltage or under-voltage. Check the A15 preregulator and the boards it feeds. |
| POWER SUPPLY HOT | H | Over-temperature: the A8 supplies shut down and the fan runs at full speed. Room must be under +55 °C (131 °F) with 6 inches of space around the unit. |
| CAUTION: AIR FLOW RESTRICTED: CHECK FAN FILTER | H | The air flow detector on A8 sees low air flow. Clean the fan filter and run with all covers on. |
Hardware error on your 8719A? Analyzer Repair Inc. repairs and calibrates the HP 8719A in-house in Cocoa, Florida, including source, phase lock, sampler and test set faults. Free estimate once the unit is in our lab. Contact us for service.
Message list based on the HP 8719A/8720A/8720B Service Manual (08720-90108): Isolate Faulty Group, Power Supply and Source sections.
HP 8719A Replaceable Parts – click to expand
HP 8719A Replaceable Assemblies and Part Numbers
These are the major replaceable assemblies in the HP 8719A, with their HP / Agilent part numbers. Option-specific assemblies are only present if your 8719A has that option installed. "Exchange" numbers are rebuilt units traded for your old assembly.
| Reference | Assembly | HP part number | Option |
|---|---|---|---|
| A1 | Front Panel Keyboard | 08720-60016 | |
| A2 | Front Panel Interface Board | 08753-60091 | |
| A4, A5, A6 | Second Converter | 08415-60004 | |
| A7 | ALC Board | 08415-60007 | |
| A8 | Post Regulator Board | 08720-60008 | |
| A8 | Post Regulator Board (Exchange) | 08720-69008 | |
| A9 | CPU Board | 08719-60006 | |
| A9 | CPU Board (Exchange) | 08719-69006 | |
| — | Firmware | 08719-60003 | |
| A10 | Digital IF Board | 08753-60095 | |
| A10 | Digital IF Board (Exchange) | 08753-69095 | |
| A11 | Phase Lock Board | 08415-60011 | |
| A11 | Phase Lock Board (Exchange) | 08415-69011 | |
| A12 | Reference Board | 08720-60012 | |
| A12 | Reference Board (Exchange) | 08720-69012 | |
| A13 | Fractional-N Analog Board | 08415-60013 | |
| A13 | Fractional-N Analog Board (Exchange) | 08415-69013 | |
| A14 | Fractional-N Digital Board | 08415-60014 | |
| A14 | Fractional-N Digital Board (Exchange) | 08415-69014 | |
| A15 | Preregulator | 08753-60098 | |
| A15 | Preregulator (Exchange) | 08753-69098 | |
| A16 | Rear Panel Board | 08753-60094 | |
| A16 | Rear Panel Board (Exchange) | 08753-69094 | |
| A17 | Motherboard (riveted to card cage and frame) | 08720-60011 | |
| A18 | Display | 2090-0210 | |
| A19 | Graphics System Processor | 08753-60202 | |
| A19 | Graphics System Processor (Exchange) | 08753-69202 | |
| A51 | Interface Board | 08415-60051 | |
| A52 | Pulse Generator (includes bias board) | 5086-7456 | |
| A52 | Pulse Generator (Exchange) | 5086-6456 | |
| A53 | Mixer/Amp (includes bias board) | 08415-60068 | |
| A53 | Mixer/Amp (Exchange) | 08415-69068 | |
| A54 | YIG 2, 8 to 13.5 GHz | 08719-60005 | |
| A55 | YIG 1, 2 to 8 GHz | 5086-7470 | |
| A55 | YIG 1, 2 to 8 GHz (Exchange) | 5086-6470 | |
| A56 | Lower Front Panel Board | 08415-60056 | |
| A57 | Fixed Oscillator 3.8 GHz | 86222-60007 | |
| A58 | Modulator | 08415-60058 | |
| A60, A61 | Bias Tee | 5086-7458 | |
| A60, A61 | Bias Tee (Exchange) | 5086-6458 | |
| A62, A63 | Directional Coupler | 08720-60029 | |
| A64, A65, A66 | Sampler | 5086-7457 | |
| A64, A65, A66 | Sampler (Exchange) | 5086-6457 | |
| A67 | Power Splitter | 5086-7408 | |
| A68 | Microwave Attenuator 8 GHz max | 0955-0216 | |
| A69 | Step Attenuator | 83595-60019 | |
| A70 | Fixed Attenuator 3 dB | 0955-0427 | |
| A71 | Fixed Attenuator 6 dB | 0955-0462 | 003 |
| S1, S2, S3 | Microwave Switch | 08415-60057 | |
| S4 | Transfer Switch | 08720-60006 |
Part obsolete or unavailable? Many 8719A assemblies are no longer sold by Keysight. Analyzer Repair Inc. does not sell parts; we repair the 8719A, including these boards and modules, at the component level in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.
Part numbers from the HP 8719A/8720A/8720B Service Manual (08720-90108), Replaceable Parts, Figure 2 "Major Assemblies". They are listed for reference and identification only.