Keysight (Agilent HP) E8361C Repair Service

E8361C PNA Network Analyzer 10 MHz to 67 GHz
Send us your Keysight Agilent E8361C Network Analyzer for full repair and calibration. Our veteran-owned lab offers free estimates and quick turnaround.
10 MHz to 67 GHz, 2-ports with one source and 4-ports with two sources, source and receiver attenuators, bias-tees, pulse generators and modulators, noise figure, and best RF performance.
kesyight-e8361c
Any failures or unforeseen issues identified during the calibration phase will be detailed in an estimate submitted for your approval prior to any further action. Repair charges are determined by the actual time and materials required. Please be aware that customers are responsible for all associated shipping costs, to and from our location. This initial estimate is provided free of charge.
E8361C Specifications – click to expand

E8361C Specifications

94 dB of dynamic range and

E8361C Options – click to expand

E8361C Options

  • Time domain for 6 GHz model N52310-010
  • Time domain for 13.5, 20, 40 or 50 GHz model N52300-010
  • Frequency-offset measurements N52300-080
  • Scalar-calibrated converter measurements
  • (Option 080 required)
  • N52300-082
  • 4-port measurement application N52300-550
  • N-port capabilities for 6, 13.5 or 20 GHz model N52310-551
  • N-port capabilities for 40 or 50 GHz model N52300-551
Agilent / HP E8361C Error Codes – click to expand

Agilent E8361C Error Messages

Error and fault messages for the Agilent E8361C network analyzer (67 GHz), with the assemblies the service manual points to.

E8361C on-screen error messages

MessageMeaning and where to look
PHASE LOCK LOSTThe A11 phase lock board sees too little reference-receiver signal to lock. Cause can be in the source, signal separation (couplers, switch) or receiver path. Check the A10 frequency reference output and the reference receiver first.
SOURCE UNLEVELEDOn the E8361C check W38/W39 from the A23/A24 SOMA 70s to A16 and W40 to the A21 SOMA 50. One port only: replace that SOMA 70. Both ports: replace the A16 test set motherboard.

E8361C failed performance test – likely cause

Failed testWhat it points to
Source power accuracy / linearityRun the source calibration adjustment; if it still fails, the source (A12 source) is suspect.
Source maximum power outputFollow the signal through the separation path (switch, couplers, attenuators) to find the loss.
Frequency accuracyMeasure the rear-panel 10 MHz REF OUT; more than about 10 Hz off calls for the 10 MHz reference adjustment.
Trace noiseRarely fails alone; run the receiver calibration adjustment, then suspect the A6 SPAM board.
Receiver compression / noise floor / dynamic accuracyPoints to the A31–A34 receivers or the A6 SPAM board. Receivers are identical, so swapping two channels confirms a bad one.
Calibration coefficientsTracking terms only: run the receiver calibration adjustment. Any other error term failing means a hardware fault.
System crosstalkLoose RF cable, or isolation loss in the receivers or the receiver/test set motherboard. Tighten all cables and receiver screws first.

SCPI error ranges

RangeClass
−100 to −199Command errors
−200 to −299Execution errors
−300 to −399Device-specific errors
−400 to −499Query errors

Hardware error on your E8361C? Analyzer Repair Inc. repairs and calibrates the Agilent E8361C in-house in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

Based on the Agilent E8361C PNA Service Guide (E8361-90008).

Agilent / HP E8361C Replaceable Parts – click to expand

Agilent E8361C Replaceable Assemblies and Part Numbers

Major replaceable assemblies for the Agilent E8361C, from the Agilent E8361C PNA Service Guide (E8361-90008).

ReferenceAssemblyAgilent part numberNotes
A1Keypad assemblyN5230-40002
A2Display assemblyN5230-60045
A3Front panel interface boardN5230-60132
A4Power supply assembly0950-4599
A6SPAM boardE8356-60006
A8Fractional-N synthesizer boardE8364-60099A9 second Frac-N with Option 080
A10Frequency reference boardE8364-60136
A11Phase lock boardE8364-60137
A12Source 20 assemblyE8361-60002Exchange E8361-69002
A13Frequency offset receiver boardE8364-60097Option 080
A14System motherboardE8364-60100
A15CPU board, 1.1 GHzE8364-60204
A16Test set motherboardE8364-60138
A17LOMA 125087-7247Exchange 5087-6247
A18MA 245087-7248Exchange 5087-6248
A19Splitter5087-7139
A20LODA5087-7777Exchange 5087-6777 (was 5087-7129)
A21SOMA 505087-7130Exchange 5087-6130
A22Switch5087-7238Exchange 5087-6238
A23, A24SOMA 705087-72492 required
A25, A26Test port couplers5087-7225
A27–A30First converters (mixers)5087-7258Exchange 5087-6258; 4 required
A31–A34Receiver modulesE8364-601344 required
A35Receiver motherboardE8364-60135
A36, A3750 dB source step attenuators84905-60001Option UNL
A38, A39Bias tees5086-7020Option UNL
A4570 GHz reference switch5087-7271
A49IF multiplexer boardE8361-60043
A41Programmed hard disk driveN5230-60048Parallel ATA
B1Fan3160-10853 required

Part obsolete? Many E8361C assemblies are no longer sold new. Analyzer Repair Inc. repairs E8361C boards and RF modules at the component level in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

From the Agilent E8361C PNA Service Guide (E8361-90008).

Located in: Network Analyzers