Keysight (Agilent HP) 8720C Repair Service

8720C S-parameter Network Analyzer
Keep your HP 8720C Network Analyzer in service with our repair and calibration. We specialize in unsupported equipment. Free evaluations.
Keysight Agilent HP 8720C vector network analyzers perform complete characterization of RF components.
8720es
Any failures or unforeseen issues identified during the calibration phase will be detailed in an estimate submitted for your approval prior to any further action. Repair charges are determined by the actual time and materials required. Please be aware that customers are responsible for all associated shipping costs, to and from our location. This initial estimate is provided free of charge.
8720C Specifications – click to expand

8720C Specifications

Measurement Rate (typical, 201-point sweep):.

SpecificationValue
Minimum frequency50 MHz
Maximum frequency20 GHz
Frequency resolution (std)100 kHz
Frequency accuracy10 ppm
Maximum power+10 dBm
Minimum power-65 dBm
Power resolution0.1 dB
Power flatness±2.0 dB
Power sweep range20 dB
Receiver sensitivity (> 2 GHz)-93 dBm
System dynamic range (> 2 GHz)103 dB
8720C Options – click to expand

8720C Options

Options: Opt 001 1 Hz Frequency Resolution. Opt 010 Time Domain Capability. Opt 011 Direct-Access Receiver Configuration. Opt 802 Add HP 9122C Dual Disk Drive. Opt 003 High Forward (S21) Dynamic Range.

HP 8720C Error Messages – click to expand

HP 8720C Error Messages

The HP 8720C (50 MHz to 20 GHz) reports faults as text messages on screen. Hardware (H) messages point to a failed assembly; user (U) messages mean a setup, calibration or cable issue; (M) messages are information.

8720C notes

  • The 8720C source is phase locked through the R sampler; a missing or weak R signal shows up as phase lock errors.
  • Normal CW power at the 8720C test port is about +10 dBm ±2 dB; low power points to the source group.
  • The rear-panel A15 green LED should be on and the red LED off, and all nine A8 green LEDs on, before troubleshooting anything else.

8720C hardware error messages

MessageTypeMeaning
PHASE LOCK CAL FAILEDHThe phase lock calibration failed. Either the R sampler or its control and bias voltages are faulty, or the source pretune is off. Check the green sampler control wire (about +0.2 V) and the ±15 V bias.
Other phase lock error messagesHAny phase lock error on screen means the source group (A11 phase lock, YIG oscillator, A12 reference, A14 fractional-N) or the R sampler path needs checking.
POWER SUPPLY SHUT DOWN!HOne or more A8 post-regulator supplies shut down from over-current, over-voltage or under-voltage. Check the A15 preregulator and the boards it feeds.
POWER SUPPLY HOTHOver-temperature: the A8 supplies shut down and the fan runs at full speed. Room must be under +55 °C (131 °F) with 6 inches of space around the unit.
CAUTION: AIR FLOW RESTRICTED: CHECK FAN FILTERHThe air flow detector on A8 sees low air flow. Clean the fan filter and run with all covers on.

Hardware error on your 8720C? Analyzer Repair Inc. repairs and calibrates the HP 8720C in-house in Cocoa, Florida, including source, phase lock, sampler and test set faults. Free estimate once the unit is in our lab. Contact us for service.

Message list based on the HP 8719C/8720C Service Manual (08720-90138): Isolate Faulty Group, Power Supply and Source chapters.

HP 8720C Replaceable Parts – click to expand

HP 8720C Replaceable Assemblies and Part Numbers

These are the major replaceable assemblies in the HP 8720C, with their HP / Agilent part numbers. Option-specific assemblies are only present if your 8720C has that option installed. "Exchange" numbers are rebuilt units traded for your old assembly.

ReferenceAssemblyHP part numberOption
A1Front Panel Keyboard08720-60087
A2Front Panel Interface Board08753-60091
A4, A5, A6Second Converter08415-60004
A8Post Regulator Board08720-60008
A8Post Regulator Board (Exchange)08720-69008
A9CPU Board08720-60040
A9CPU Board (Exchange)08720-69040
A10Digital IF Board08753-60095
A10Digital IF Board (Exchange)08753-69095
A11Phase Lock Board08720-60109
A11Phase Lock Board (Exchange)08720-69109
A12Reference Board08720-60012
A12Reference Board (Exchange)08720-69012
A13Fractional-N Analog Board08720-60049
A13Fractional-N Analog Board (Exchange)08720-69049
A14Fractional-N Digital Board08720-60050
A14Fractional-N Digital Board (Exchange)08720-69050
A15Preregulator08753-60098
A15Preregulator (Exchange)08753-69098
A16Rear Panel Board08720-60044
A17Motherboard (riveted to card cage and frame)08720-60051
A18Display2090-0210
A18Display (Exchange)5180-8484
A19Graphics System Processor08753-60170
A19Graphics System Processor (Exchange)08753-69170
A51Test Set Interface Board08720-60053
A52Pulse Generator (includes bias board)5086-7456
A52Pulse Generator (Exchange)5086-6456
A53Low Band Microcircuit5086-7583
A53Low Band Microcircuit (Exchange)5086-6583
A55YIG Oscillator 2.4 to 20 GHz08720-60082
A56Lower Front Panel Board08415-60056
A57Fixed Oscillator 3.8 GHz08720-60073
A58M/A/D/S Microcircuit5086-7519
A58M/A/D/S Microcircuit (Exchange)5086-6519
A59Source Interface Board08720-60052
A60, A61Bias Tee5086-7458
A60, A61Bias Tee (Exchange)5086-6458
A62, A63Directional Coupler08720-60029
A64, A65, A66Sampler5086-7457
A64, A65, A66Sampler (Exchange)5086-6457
A68Microwave Attenuator 6 dB0955-0462
A69Step Attenuator83595-60019
S2, S3Microwave Switch08415-60057
S4Transfer Switch08720-60006
S4Solid State Transfer Switch5086-7642006

Part obsolete or unavailable? Many 8720C assemblies are no longer sold by Keysight. Analyzer Repair Inc. does not sell parts; we repair the 8720C, including these boards and modules, at the component level in Cocoa, Florida. Free estimate once the unit is in our lab. Contact us for service.

Part numbers from the HP 8719C/8720C Service Manual (08720-90138), Chapter 16 "Replaceable Parts", Figure 16-2 "Major Assemblies". They are listed for reference and identification only.

Located in: Network Analyzers